A reliable, code-compliant insulation system for new construction and renovations. Driedger Brothers installs batt and poly insulation with precision, ensuring full coverage, proper vapour barriers, and maximum R-value performance.

What is Batt & Poly Insulation?

Batt insulation consists of pre-cut panels or rolls of fibreglass, mineral wool, or natural fibre materials designed to fit snugly between wall studs, floor joists, and ceiling rafters. When paired with a polyethylene (poly) vapour barrier, batt insulation is a tried-and-true, code-compliant insulation system used extensively across Ontario in residential and light commercial construction.

Where Batt & Poly Insulation is Used

Batt insulation is most commonly installed in interior walls, attic floors, garage ceilings, and basement walls. The poly vapour barrier is applied to the warm side of the wall assembly to prevent moisture-laden interior air from reaching the cold sheathing and causing condensation and mould. Together, the batt-and-poly system meets Ontario Building Code requirements for most residential applications.

Batt & Poly vs. Spray Foam — Choosing the Right Product

Batt and poly remains a popular choice for new construction and renovations where budget is the primary consideration and the wall and ceiling framing is regular and unobstructed. For irregular framing, existing construction, or applications requiring superior air and moisture control, spray foam is typically the better investment. Driedger Brothers works with homeowners and contractors to select the most appropriate product for each application.

Professional Installation Matters

Even a product as straightforward as batt insulation must be installed correctly to perform as rated. Common issues include compression, gaps around electrical boxes, and incorrectly placed vapour barriers. Our crew has 20+ years of experience ensuring every batt is cut to fit, every cavity is fully covered, and every vapour barrier is properly sealed to deliver the R-value you are paying for.

Frequently Asked Questions

What R-value does batt insulation provide?

Fibreglass batt insulation typically provides R-12 to R-22 depending on the thickness and product. A standard 2x6 wall cavity filled with fibreglass batt achieves approximately R-19 to R-22.

Do I need a vapour barrier with batt insulation in Ontario?

Yes. Ontario Building Code requires a vapour barrier (polyethylene sheet) on the warm side of insulation in cold climate wall assemblies. This prevents interior moisture from migrating into the wall cavity and causing condensation.

Can batt insulation be added to an existing finished space?

Adding batt insulation to an existing finished wall typically requires opening the wall. For existing enclosed spaces, blown-in insulation is often a better option as it can be installed through small holes without full removal of drywall.

(519) 550-6368